ST 2110
Example : Prerequisite⚓
ST 2110 network including a Level 3 switch with 25G ports, a PTP master clock (2-step clock) and NMOS nodes with ST 2110 endpoints (following AMWA specifications) must be set-up before WebRCS configuration. For more information, see the corresponding application note on https://www.analogway.com.
All signals within the same module (2 modules per card) must use the same bit rate type (Integer or Fractional).
ST 2110 audio / video stream routing can be set via an external NMOS controller.
The video stream can also be set via:
SDP file
manually.
PTP synchronization applies to each module individually.
Note :
The routing of ST 2110 audio / video streams to the LivePremier device inputs must be done through the interface of a selected NMOS controller after AVoIP preconfiguration.