Configure the RC400T network
On the front panel, go to Remote Device Network > Remote device LAN settings.
Select a device slot, set the IP address of the LivePremier unit and Apply (192.168.2.140 by default).
If needed, repeat in the other device slots to add more connected units.
If needed, go to Console Network, set the IP address of the RC400T and Apply (192.168.2.130 by default).
The connection status is displayed on screen.
Example : If the connection is not starting:⚓
- Check that both IP addresses are on the same network and subnet.
- Check that no device has the same IP address (prevent IP conflicts).
- Check that all network configurations have been applied.
- Check that the LivePremier unit and RC400T have the latest firmware version installed.
- Check the network cables for the RC400T and a hub or switch (if involved).